Biomerieux Observa User Manual

On By In Home

Biomerieux Observa User Manual' title='Biomerieux Observa User Manual' />NATURA AMORE ARTE ANIMALI CITT NATALIZI RICORRENZE PAESAGGI FIORI VARIE Per impostare come sfondo desktop Cliccare sullimmagine con il tasto destro del. BACTALERT 3D Microbial Detection Systems Overview Get innovation in septicemia diagnosis for any size laboratory with the BACTALERT 3D automated microbial. BACTALERT 3. D Microbial Detection Systems Overview clinical diagnostics products. The BACTALERT 3. D family of products brings you sophisticated automated microbial detection systems with advantages in every dimension of blood culture testing from safety and design to recovery and accuracy. They provide optimal environments for the recovery of a wide range of microorganisms, including bacteria, fungi and mycobacteria. All this in a single innovative platform thats the most compact,modular and flexible system available. Flexible scalable to suit any lab. The VITEK 2 system offers Windows based, userfriendly software bidirectional interface epidemiology report module Advanced Expert System AES software. VITEK 2 Product Safety. Optimizing Collection to Care. The VITEK 2 Compact system answers QC laboratory testing needs for fast and accurate microbial. The BACTALERT system is a flexible and scalable family of three instruments with various capacities so they offer advantages to suit different sized labs with different needs. Add additional testing capacity as you need it, thanks to expandable design. Small footprint stackable units fit any laboratory layout. Choose number of incubator modules for your labs annual bottle testing volume. Configure each incubator module to perform blood culture or body fluid, platelet sterility testing, andor mycobacteria testing, by drawer. BACTALERT 3. D 2. Photo-logo-groupe-BioMerieux_0_1400_331.jpg' alt='Biomerieux Observa User Manual' title='Biomerieux Observa User Manual' />Biomerieux Observa User ManualCapacity and capability combined. Four incubator drawers of 6. Install Teamspeak On Ubuntu Server. Control module handles up to 6 incubatormodules for capacity up to 1. Horizontal and vertical modularity minimize physical strain. Sample loading flexibility with left or right handed sample loading drawers. Drawers configured for blood or mycobacterium cultures. BACTALERT 3. D 1. Combo Surprisingly compact, remarkably complete. BACTALERT 3. D 6. Simply smaller. 60 cell capacity 3,6. Optimized space saving cost effective design so any laboratory can benefit from BACTALERT 3. D technology. Configurable for blood or mycobacterium cultures. Workflow thats as easy as 1 2 3. Sometimes, the simplest things make the biggest difference. As labs face the challenges of higher volumes, demand for reduced turnaround and the need to use staff resources effectively, smart workflow is critical. The efficient workflow you get with BACTALERT 3. D instrument helps you meet those challenges, reduce risk of error and gain peace of mind through easy and intuitive bottle handling. In fact, the bottle handling process is as easy as 1 2 3 with the three step bottle loading process of Touch, Scan, Load Exclusive touch screen operation enables text free control, facilitates bottle handling and provides instant visual and audio alerts for positive bottles. Bar code scanner reads bottle ID and LIS accession numbers for faster, easier bottle entry. Patented cell flags in each cell instantly recognize bottle movements and let you load bottles anywhere in the system. Easy procedure minimizes training requirements and enhances productivity. Safe and reliable media. The BACTALERT system uses media cleared for use with blood, sterile body fluids and platelets, as well as specialized media for detection of mycobacteria. Unique colorimetric technology outshines other technology by reducing false negatives due to delayed bottle entry. Triple layer bottle design ensures appropriate environment for reliable recovery of microorganisms. Safety and efficiency are ensured with plastic blood culture media, pioneered by bio. Mrieux. Shatter resistant bottles reduce biohazard exposure risk. Light weight bottles offer cost effective shipping and disposal without compromising results. Technical specifications and reference numbers. BACTALERT 3. D 2. Incubator Module 2. Height. 36 inches. Width. 19. 5 inches. Length. 24. 3 inches. Unload Weight. 20. Load Weight. 23. 3 lbs. Capacity. 24. 0 cells 6. Electric Power Service Requirements. Hz1. 102. 40v. Power Consumed in Watts. VAC 2. 56 Watts idle, 6. Bank Of England Font there. Watts typical Heat Dissipated. BTUHr. 2. 84. 0 maximum Sound Emission. B 2. 43. 01. 0 Bac. TALERT Controller Module. Bac. TALERT Incubator Module Left w Racks. Bac. TALERT Incubator Module Right w Racks. BACTALERT 3. D 1. Combo. 24. 70. 01 BACTALERT 1. Combination Module Right. BACTALERT 1. 20 Combination Module Left. BACTALERT 3. D 6. Bac. TALERT 3. D 6. Data Management Options. BACTALERT 3. D Select software provides basic data management functions. Five customizable data fields can be used to add patient demographics or culture information. Reports can be generated based upon data entered into customizable fields or instrument generated data. Reports are customizable with sorting and printing capabilities. BACTALERT 3. D Select. Link software offers the same capabilities as BACTALERT 3. D Select but in addition has an interface to the Laboratory Information System LIS to eliminate manual data entry. This option is perfect for laboratories that rely on their LIS for most of their reporting needs. BACTALERT 3. D Signature software includes OBSERVA, a comprehensive, flexible and customizable data management system. Signature is an ideal choice for demanding environments where site specific operating modes and customized data manipulation and reporting are necessities. It offers user defined data fields with options lists, configurable icons to launch functions or print reports, numerous pre programmed reports which are also customizable, and the ability to query the database by virtually any parameter. The BACTALERT 3. D Signature system includes an interface from BACTALERT 3. D to the LIS. Please contact your local bio. Mrieux representative for product availability. BACTALERT 3. D HEALTHCARE PUBLICATIONSStandard Media Recovery Mirret S, Reller LB, Petti CA, Woods CW, Vazirani B, Sivadas R, and Weinstein MP. Controlled Clinical Comparison of Bac. TALERT Standard Aerobic Medium with BACTEC Standard Aerobic Medium for Culturing Blood. J. Clin Microbiol. Bernard D, Verschraegen G, Claeys G, Lauwers S, Rosseel P. Bilophila wadsworthia bacteremia in a patient with gangrenous appendicitis. Clin Infect Dis. June 1. Standard vs. FAN Media Weinstein MP, Mirrett S, Reimer LG, Wilson ML, Smith Elekes S, Chuard CR, Joho KL, Reller LB. Controlled evaluation of Bac. TALERT standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol. Wilson ML, Weinstein MP, Mirrett S, Reimer LG, Feldman RJ, Chuard CR, Reller LB. Controlled evaluation of Bac. TALERT standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia. J Clin Microbiol. Mc. Donald LC, Fune J, Gaido LB, Weinstein MP, Reimer LG, Flynn TM, Wilson ML, Mirrett S, Reller LB. Clinical importance of increased sensitivity of Bac. TALERT FAN aerobic and anaerobic blood culture bottles. J Clin Microbiol. Mirrett S, Everts RJ, Reller LB. Controlled Comparison of Original Vented Aerobic FAN Medium with New Nonvented Bac. TALERT FA Medium for Culturing Blood. J Clin Microbiol. Mirrett S, Petti CA, Woods CW, Magadia R, Weinstein MP, Reller LB. Controlled Clinical Comparison of the Bac. TALERT FN and the Standard Anaerobic SN Blood Culture Medium. J Clin Microbiol. FAN vs. BACTEC Plus Ziegler R, Johnscher I, Martus P, Lenhardt D, Just HM. Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media in automated blood culture systems to detect bloodstream infections. J Clin Microbiol. Pohlman JK, Kirkley BA, Easley KA, Basille BA, Washington JA. Controlled clinical evaluation of BACTEC Plus AerobicF and Bac. TALERT aerobic FAN bottles for detection of bloodstream infections. J Clin Microbiol. Jorgensen JH, Mirrett S, Mc.